Click to download product brochure  (PDF)
Click for Aculas-AM Series List
AM-100 AM-100
AM-100C AM-100C
AM-100D AM-100D
AM-100W AM-100W
AM-102 AM-102
AM-102B AM-102B
AM-102V AM-102V
AM-151 AM-151
AM-200 AM-200
AM-201 AM-201
LLLT Laser Hood
AM-320 AM-320
Click for Megalas-AM-800
Laser Irradiation System Laser Irradiation System
CE Certification Laser Hood CE Certification Laser Hood
Click for Aculas-HB Series List
Auricular
HB-150E
HB-150E
Nasalis
HB-150N
HB-150N
Laser Shower
HB-850
HB-850
Erectile Dysfunction
HB-950
HB-950
Click for emLas Series List
Laser Wrap
emLas-150
emLas-150
emLas-250 emLas-250
emLas-320 emLas-320
Auricular
emLas-520
emLas-520
Hair Loss
emLas-800
emLas-800
Click for Klas Series List
Laser Acupuncture Laser Acupuncture
Auricular Laser Acupuncture Auricular Laser Acupuncture
Dental LLLT Unit Dental LLLT Unit
Nasalis LLLT Unit Nasalis LLLT Unit
Multiple Applications LLLT Unit Multiple Applications LLLT Unit
5-in-1 LLLT Unit 5-in-1 LLLT Unit
250 ~ 450mW Infrared Laser
6-in-1 Infrared Laser 6-in-1 Infrared Laser
Intelligent LLLT Dose Unit
Intelligent LLLT Dose Unit Intelligent LLLT Dose Unit
 
   
  Click for Accessories & Parts
Click to Enlarge
Click to Enlarge
Aculas®-HB-950 Download PDF File
Multi-channel Digital LLLT System
(Erectile Dysfunction Treatment)


Aculas-HB-950
is developed from "Laser Biostimulation" theory and "Low Level Laser Therapy (LLLT)" medical approval. This patented product is made using the combination of modern laser diode technology and computerized digital control.

Erectile dysfunction, sometimes referred to as impotence, is the inability for a sexually active male to obtain and sustain an erection for sexual purposes. In the past, this has been very embarrassing for men, and a source of anxiety for their partners, and, in fact, there has been very little diagnostic testing or treatments available up until very recently.

The LLLT will prevent the breakdown of nitric oxide, a chemical messenger that promotes relaxation and opening of the blood vessels that supply erectile tissue in the penis. Under the influence of nitric oxide, these vessels expand and stay dilated. Increased blood flow makes erectile tissue swell and compress the veins that carry blood out of the penis, resulting in a full erection.

Aculas-HB-950 is specially designed for erectile dysfunction (ED) treatment. With the advent of an effective and safe LLLT, the entire evaluation and treatment process for ED has become revolutionized.

 
  • Laser beams reach the treating target by penis cup with accessing the laser modules for accurate positioning.
  • Microprocessor-based control, with the functions of self-diagnostic check and error detection, can automatically detect faulty alarm channel(s).
  • User-friendly single function key to set the therapy process.
  • Dynamic large size (80x50 mm) LCD with blue backlit display for clear reading.
  • Musical auto time off on completion of therapy cycle.
  • Patented laser modules directly contact the treatment area without the risk of laser leakage for complete protection.
Operation Environment 0 ~ 50 °C (32 ~ 122 °F); 10 ~ 95%RH (Non-condensing)
Storage Environment -20 ~ 85 °C (4 ~ 185 °F); 10 ~ 95%RH (Non-condensing)
No. of Channels 5
Time Setting 30 Minutes (Auto Setting)
Frequency Setting Continuous (Auto Setting)
Music Alert Stop and Fault
Power Input Voltage 90V AC ~ 264V AC
Power Input Frequency 47Hz ~ 63Hz
Power Input Current Max. 1.0A (115V AC), 0.5A (230V AC)
Power Supply Protection Short Circuit and Overload; Auto Recovery Mode
Verification EMC Directive 93/42/EEC (Operation Environment: Medical Electrical Equipment)
Standard Applied: IEC 60601-1 and EC 60601-1-2
Enclosure Material ABS 94HB (Flame Class Rating UL 94HB)
Medical Device Certificate GMP  GMP (Good Manufacturing Practice) ISO 13485
Shipping Dimensions 39(L) x 13(W) x 30(H) cm; 15.4(L) x 5.1(W) x 11.8(H) in
Shipping Weight 3.3 Kg (7.3 Lbs)
Laser Modules with Penis Cup

Click to Enlarge

 

Quantity of Laser Module 5
Laser Material Semiconductor Laser Diode AlGaAs
Wavelength
& Output Power
780nm…50mW x 5
808nm…50mW x 5
Contact Plate Material Surgical Stainless Steel
Optional Plastic Wrap For multiple users application, it is recommended to wrap around the user's penis with the qualified plastic wrap.
LP-5
Click to Enlarge
Aluminum Case WC-122
Dimensions 375(L) x 285(W) x 115(H) mm
14.8(L) x 11.2(W) x 4.6(H) in.
Click to Enlarge
Weight 1.43 Kg (3.15 Lb)
Model No. 780nm
@ 50mW
808nm
@ 50mW
Total Output Power
HB-950A755 5   250 mW
HB-950A855   5 250 mW
Therapy Time Frequency Session (Times)
(Minutes) (Time/Week) Avg. Max.
30 2 6 ~ 8 12
About 20% users must have 12 sessions to get better effectiveness.

Konftec Corporation © Copyright 2004-2010, All Rights Reserved

The True Medicine  
   CE Verification     Verification
   GMP Good Maufacturing Practice   GMP
 
We Are Providing
  Warranty   Warranty
  Money Back Guarantee   Money Back

     
   
Clinical Report:
Laser light - a new, non invasive treatment for Erectile Dysfunction: a placebo-controlled, single blinded pilot study
Download PDF File Aculas-HB
User's Guide