Home
    Home > Home Therapy > Products > emLas > emLas-250  

Click to Select Models
Click to Select Klas Models
Klas Series
Laser Acupuncture Laser Acupuncture
Auricular Laser Acupuncture Auricular Laser Acupuncture
Dental LLLT Unit Dental LLLT Unit
Multiple Applications LLLT Unit Multiple Applications LLLT Unit
5-in-1 LLLT Unit 5-in-1 LLLT Unit
Intelligent LLLT Dose Unit
Intelligent LLLT Dose Unit Intelligent LLLT Dose Unit
Click to Select Megalas Models
Laser Irradiation System Laser Irradiation System
CE Certification Laser Hood CE Certification Laser Hood
   
  Click for Accessories & Parts
Click to EnlargeClick to Enlarge emLas®-250  Download PDF File
Cordless System
(5 Lasers; 250 mW)
(LLLT for Aesthetic Applications)
(Pain Management)
The revolutionary with multiple lasers
Performance & Safety
Multiple lasers can be delivered simultaneously.
Accurate and variable irradiance dose control across treatment area.
Eliminates the possibility of light affecting the eyes.
Cordless operation
Medical Laser Power
The real laser power output (250 mW) from the Laser Wrap.
CE Medical Verification
ISO 13485 Quality System Certificate
Reliability
Equipped with the industrial grade laser diodes and modules.
Temp. rating : 60°C
MTBF (Mean Time Between Failures) > 5,000 Hours

emLas-250 is developed to apply Low Level Laser Therapy (LLLT) as a non-invasive, non-toxic therapy for a wide variety of medical conditions with the hand-free and mobile laser wrap system.

emLas-250 is patented and made using the combination of modern laser diode technology, innovative optics design and computerized digital control.

emLas-250 is applying the RED lasers, INFRARED lasers or the COMBINATION lasers for the specific LLLT with the best effectiveness.

emLas-250 equipped with RED lasers can be applied LLLT for the aesthetic treatments:

Body contouring in the waist
Cellulite reduction
Skin tightening

emLas-250 equipped with INFRARED lasers can be applied LLLT treatments for pain managements include:
Acute & Chronic Joint Pain
Arthritis
Frozen Shoulder
Low Back Pain
Post Operative Tissue Pain
Sports Injuries
Sprains & Strains
Tennis Elbow

Hand-free
Mobile
Click to Enlarge
  • Operation
  • Features
  • Specifications
  • Model No.
Effective   Specific laser power for the hearing diseases:
Specially designed laser beam evenly irradiates the inner ear.
Advanced integrated circuit designed by Konftec with automatic power control(APC) to maintain the specific power output.
Industrial grade laser diodes with temperature rating of 60 °C and MTBF (Mean Time Between Failures) > 5,000 hours.
Safe   Konftec's integrated circuit design for all laser modules provide full protection of:
EDS (Electrostatic Discharge)
over-temperature
soft-start
Easy to Use   Cordless operation powered by battery pack for hand free and mobile treatment.
Powered by one rechargeable Li-ion battery with the capacity of 1,700 mAh for longer time operation.
Dynamic blue LED display for clear reading.
To set the last therapy process with " Start " button.
Controller
Operation Environment 0 ~ 50 °C (32 ~ 122 °F); 10 ~ 95%RH (Non-condensing)
Time Setting 1 ~ 60 Minutes (Min. Setting Segment 1 Minute); Auto Stop
Beeper Alert Setting and Stop
Power Supply Rechargeable Li-ion Battery
Controller Enclosure Color White or Black
Verification EMC Directive 93/42/EEC
(Operation Environment: Medical Electrical Equipment)
Standard Applied: IEC 60601-1 and EC 60601-1-2
Medical Device Certificate ISO 13485: 2003
Shipping Dimensions 29.5(L) x 22.5(W) x 12(H) cm; 11.6(L) x 8.9(W) x 4.7(H) in
Shipping Weight 1.2 Kg (2.6 Lbs)
Laser Wrap Module LW-5
Quantity of Laser Module 5 Click to Enlarge Click for Illustration
Laser Material Semiconductor Laser Diode
660nm… AlGaInP
780nm… AlGaAs
808nm… AlGaAs
Wavelength
… Output Power
660nm… 50mW
780nm 50mW
808nm… 50mW
Contact Plate Material Stainless Steel
Option Limited Selectable Laser Module Quantity, Wavelength & Output Power
Battery Charger / AC Power Supply Unit WP-152
Power Input Voltage 90V AC ~ 264V AC Click to Enlarge
Power Input Frequency 47Hz ~ 63Hz
Power Input Current Max. 0.5A (115V AC), 0.25A (230V AC)
Power Supply Protection Short Circuit and Overload; Auto Recovery Mode
Li-ion Rechargeable Battery WB-532
Nominal Capacity (min/typ) 1620/1700 mAh Click to Enlarge
Nominal Voltage 3.7 V
Protection Over Charge
Charging Time 3.5 Hrs
Carrying Bag WC-220
Dimensions 24(L) x 20(W) x 8(H) cm
9.4(L) x 7.9(W) x 3.1(H) in.
Click to Enlarge
Weight 0.4 Kg (0.9 Lb)
Model No. Laser Wrap
Laser Module Total
Output Power
Recommended
Applications
660nm 780nm 808nm
50mW 50mW 50mW
emLas-250A Click to Enlarge   5   250 mW Pain Management
emLas-250B 5     250 mW Body Contouring
Cellulite Reduction
Skin Tightening
emLas-250C     5 250 mW Pain Management
Remarks:
Other limited laser wavelengths and output powers are available upon request.
The sizes of the laser wrap and the alternative positions of the laser modules are available upon request.
For the removal of localized deposits of adipose tissues that do not respond to diet and exercise; specifically in the areas of the waist, hips and bilateral thighs.
The True Medicine  
     CE Verification     Verification
    ISO 13485
We Are Providing
  Warranty   Warranty
  Money Back Guarantee   Money Back

     
   
Pain Management Therapy Protocol
Download PDF File emLas User's Guide
     
  Konf™-Konftec Corporation © 2023