Click to download product brochure  (PDF)
Click for Aculas-AM Series List
AM-100 AM-100
AM-100C AM-100C
AM-100D AM-100D
AM-100W AM-100W
AM-102 AM-102
AM-102B AM-102B
AM-102V AM-102V
AM-151 AM-151
AM-200 AM-200
AM-201 AM-201
LLLT Laser Hood
AM-320 AM-320
Click for Megalas-AM-800
Laser Irradiation System Laser Irradiation System
CE Certification Laser Hood CE Certification Laser Hood
Click for Aculas-HB Series List
Auricular
HB-150E
HB-150E
Nasalis
HB-150N
HB-150N
Laser Shower
HB-850
HB-850
Erectile Dysfunction
HB-950
HB-950
Click for emLas Series List
Laser Wrap
emLas-150
emLas-150
emLas-250 emLas-250
emLas-320 emLas-320
Auricular
emLas-520
emLas-520
Hair Loss
emLas-800
emLas-800
Click for Klas Series List
Laser Acupuncture Laser Acupuncture
Auricular Laser Acupuncture Auricular Laser Acupuncture
Dental LLLT Unit Dental LLLT Unit
Nasalis LLLT Unit Nasalis LLLT Unit
Multiple Applications LLLT Unit Multiple Applications LLLT Unit
5-in-1 LLLT Unit 5-in-1 LLLT Unit
250 ~ 450mW Infrared Laser
6-in-1 Infrared Laser 6-in-1 Infrared Laser
Intelligent LLLT Dose Unit
Intelligent LLLT Dose Unit Intelligent LLLT Dose Unit
 
   
  Click for Accessories & Parts
Click to Enlarge Click to Enlarge Aculas®-AM-100C Download PDF File
2-channel Digital LLLT System
(Low Level Laser Therapy)
(Laser Acupuncture)


Aculas-AM-100C 2-channel laser acupuncture system is developed from Chinese traditional acupuncture and "Laser Biostimulation" theory.
This patented product is made using the combination of modern laser diode technology and computerized digital control.

Multi-channel laser acupuncture applies the medical science of Chinese multiple needles' acupuncture and added with laser energy for extraordinary therapy achievement. Clickb to Enlarge
Laser beams reach the acupoints without piercing through the skin, thus avoiding the irony of traditional needle acupuncture and the inconsistency of correct needle depth.
Microprocessor-based control, with the functions of self-diagnostic check and error detection, can automatically detect faulty alarm channel(s).
Color-distinguished keyboard for convenient key-in.
Ten user-friendly function keys combined with numerical keys for easy setting of the therapy process.
Dynamic large size (80x65 mm) LCD with blue backlit display for clear reading.
Digitally selectable continuous wave or pulse output for wider application.
To set the last therapy process with a single function " Prog. " key for time saving and accuracy.
Operation Environment 0 ~ 50 °C (32 ~ 122 °F); 10 ~ 95%RH (Non-condensing)
Storage Environment -20 ~ 85 °C (4 ~ 185 °F); 10 ~ 95%RH (Non-condensing)
No. of Channels 2
Time Setting 1 ~ 60 Minutes (Min. Setting Segment 1 Minute)
Frequency Setting 0 Hz (Continuous Wave)
1 ~ 1,000 Hz (Min. Setting Segment 1 Hz)
Music Alert Stop and Fault
AC Power Supply Unit
Power Input Voltage 90V AC ~ 264V AC
Power Input Frequency 47Hz ~ 63Hz
Power Input Current Max. 1.0A (115V AC), 0.5A (230V AC)
Power Supply Protection Short Circuit and Overload; Auto Recovery Mode
Verification EMC Directive 93/42/EEC
(Operation Environment: Medical Electrical Equipment)
Standard Applied: IEC 60601-1 and EC 60601-1-2
Enclosure Material ABS 94HB (Flame Class Rating UL 94HB)
Medical Device Certificate GMP  GMP (Good Manufacturing Practice) ISO 13485
Shipping Dimensions 46(L) x 15(W) x 32(H) cm; 18.1(L) x 5.9(W) x 14.2(H) in
Shipping Weight 4.2 Kg (9.2 Lbs)
Laser Acupuncture Module

Click to Enlarge

 

Laser Material Semiconductor Laser Diode
660nm…AlGaInP
780nm…AlGaAs
808nm…AlGaAs
Wavelength
& Output Power
660nm…100mW
780nm…90mW
808nm…200 ~ 450mW
Laser Spot Size 0.13 cm2
Contact Area 5.3 cm2
Contact Plate Material Surgical Stainless Steel
Housing Material Stainless Steel
Option Limited Selectable Laser Diode Wavelength & Output Power
LA-1
Click to Enlarge
Auricular Laser Acupuncture Module

Click to Enlarge

 

Laser Material Semiconductor Laser Diode
660nm…AlGaInP
780nm…AlGaAs
808nm…AlGaAs
Wavelength
& Output Power

(End of Fiber)
660nm…80mW
780nm…70mW
808nm…160 ~ 400mW
Laser Spot Size 0.07 cm2
Contact Plate Material Glass Fiber
Housing Material Stainless Steel
Option Limited Selectable Laser Diode Wavelength & Output Power
LB-1
Click to Enlarge
Fiber Rod WF-422
Connection Material Stainless Steel Click to Enlarge
Rod Material Fiber
Rod Diameter 8 mm; Bent
Laser Spot Size 0.5 cm2
Transmission Ratio > 80%
Aluminum Case WC-123
Dimensions 450(L) x 330(W) x 130(H) mm
17.7(L) x 13(W) x 5.1(H) in.
Click to Enlarge
Weight 1.73 Kg (3.81 Lb)
Laser Safety Goggle WG-22x
Frame Plastic Click to Enlarge
Lens Polycarbonate with hard coating
Protection Side shields
Model No.
Aculas-
Laser Module Laser Acupuncture
Auricular Acupuncture
Wavelength 660nm 780nm 808nm 660nm 780nm 808nm
Output Power 100 mW 90 mW 200 mW 100 mW 90 mW 200 mW
AM-100C6A2        
AM-100C792        
AM-100C8B2        

Konftec Corporation © Copyright 2004-2010, All Rights Reserved

The True Medicine  
   CE Verification     Verification
   GMP Good Maufacturing Practice   GMP
 
We Are Providing
  Warranty   Warranty
  Money Back Guarantee   Money Back

     
   
  Pain Management Therapy Protocol  
   
  Laser Acupuncture Therapy Protocol  
   
  Download PDF File Aculas-AM
User's Guide
 
   
  Download PDF File Commonly Applied Acupoints  
   
  Download PDF File The Average Depth of Acupoints in Breast & Back