Aculas®-HB-150A |
 |
| Multi-channel
Digital LLLT System |
| (Acupuncture Application) |
Aculas-HB-150A is
developed from the combination of Chinese traditional acupuncture
and Western "Laser
Biostimulation" theory. This patented product is made
using the combination of modern laser diode technology and
computerized digital control.
Aculas-HB-150A is
specially designed for the laser acupuncture therapy.
|
|
 |
|
- Multi-channel laser acupuncture applies the medical
science of Chinese multiple needles' acupuncture and added with laser
energy for extraordinary therapy achievement.
- Microprocessor-based control, with the functions
of self-diagnostic check and error detection, can automatically detect
faulty alarm channel(s).
- User-friendly single function
key to set the therapy process.
- Dynamic large size (80x50 mm)
LCD with blue
backlit display for clear reading.
- Musical auto time
off on completion of therapy cycle.
- Patented laser modules directly
tap to the acupoints without the risk of laser leakage for complete protection.
|
 |
|
| Operation Environment |
0
~ 50 °C (32 ~ 122 °F); 10 ~ 95%RH (Non-condensing) |
| Storage Environment |
-20 ~ 85 °C (4 ~ 185° F);
10 ~ 95%RH (Non-condensing) |
| No. of Channels |
5 |
| Time Setting |
30 Minutes (Auto Setting) |
| Frequency Setting |
2 Hz (Auto Setting) |
| Music Alert |
Stop and Fault |
| Power Input Voltage |
90V AC ~ 264V AC |
| Power Input Frequency |
47Hz ~ 63Hz |
| Power Input Current |
Max. 1.0A (115V AC), 0.5A (230V AC) |
| Power Supply Protection |
Short Circuit and Overload; Auto Recovery Mode |
Verification |
EMC
Directive 93/42/EEC (Operation Environment: Medical Electrical
Equipment)
Standard Applied: IEC 60601-1 and EC 60601-1-2 |
| Enclosure Material |
ABS 94HB (Flame Class Rating UL 94HB) |
| Medical Device
Certificate |
GMP (Good
Manufacturing Practice) ISO 13485 |
| Shipping
Dimensions |
39(L) x 13(W) x 30(H) cm;
15.4(L) x 5.1(W) x 11.8(H) in |
| Shipping
Weight |
3.3 Kg (7.3 Lbs) |
| Double
Sided Tape |
| Tape
Size |
Width
- 24mm,
Length - 13.72 m
(capable of 500~600 tapes for laser module) |
| Tape
Class |
Medical
Grade |
| Transparency |
> 92%
( for Red & IR Range Lasers ) |
|
WA-421 |
 |
Tapping
Instruction |
 |
| Aluminum
Case |
WC-122 |
| Dimensions |
375(L)
x 285(W) x 115(H) mm
14.8(L) x 11.2(W) x 4.6(H) in. |
 |
| Weight |
1.43
Kg (3.15 Lb) |
|
|
| Model No. |
Laser Module  |
Total Output Power |
660nm
@ 50mW |
780nm
@ 80mW |
808nm
@ 80mW |
| HB-150A655 |
5 |
|
|
250 mW |
| HB-150A785 |
|
5 |
|
400 mW |
| HB-150A885 |
|
|
5 |
400 mW |
|
Konftec
Corporation © Copyright
2004-2010, All Rights Reserved |
|
|